STUDI PENGARUH PERUBAHAN TEGANGAN DAN ARUS TERHADAP SUHU PADA ALAT INKUBATOR BAYI

Authors

  • Aripin Triyanto Universitas Pamulang
  • Vandanu Adiputra Universitas Pamulang

Keywords:

inkubator, arduino, simulink

Abstract

Technological advances in the world are very important, one of which is a device to help baby safety. Because the infant mortality rate is quite high. Incubator is one solution to reduce infant mortality because the baby is not born normally. Several steps were taken to standardize the voltage, current and temperature in the incubator room. With the standards that have been set, it is hoped that it will make it easier in an emergency when the incubator is ready to use. In addition, the research development was carried out with several data collection times which were influenced by room temperature. Data obtained at certain hours with temperatures according to the use of Arduino measuring instruments and assisted by simling from the web. The following data are obtained when measuring voltage, current and temperature. With an input voltage of 100 V, we get 1.7 A and a temperature of 18.2˚C. Meanwhile, using a voltage of 225 V, obtained a current of 2.7 A and a temperature of 27.5˚C. So that the results of the voltage, current and temperature data are adjusted to the standard setting on the incubator of 220 V to 230 V with a standard temperature of 37.5 to 38.5˚C.

References

Amelia, M. (2020). Sistem Monitoring dan Pengontrolan Suhu pada Inkubator Bayi Berbasis Web. JTEV (Jurnal Teknik Elektro Dan Vokasional), 6(2), 104. https://doi.org/10.24036/jtev.v6i2.108582

Hidayati, Q., Yanti, N., & Jamal, N. (2019). Sistem Monitoring Inkubator Bayi. Jurnal Teknik Elektro Dan Komputer TRIAC, 6(2), 51–55. https://doi.org/10.21107/triac.v6i2.5989

Kesehatan Kementerian Kesehatan Surabaya, P., Dwi Ridhani, F., & Hasanah Ahniar, N. (2020). Purwarupa Penghangat Bayi Dengan Elemen Pemanas Keramik, Sensor Thermopile AMG8833 dan ESP32. Prosiding Seminar Nasional Kesehatan Poltekkes Kemenkes Surabaya 2020, 2(1), 1–7. http://semnas.poltekkesdepkes-sby.ac.id/index.php/2020/article/view/171

Padila, P., & Agustien, I. (2019). Suhu Tubuh Bayi Prematur di Inkubator Dinding Tunggal dengan Inkubator Dinding Tunggal Disertai Sungkup. Jurnal Keperawatan Silampari, 2(2), 113–122. https://doi.org/10.31539/jks.v2i2.651

Padila, P., Amin, M., & Rizki, R. (2018). Pengalaman Ibu dalam Merawat Bayi Preterm yang Pernah dirawat di Ruang Neonatus Intensive Care Unit Kota Bengkulu. Jurnal Keperawatan Silampari, 1(2), 1–16. https://doi.org/10.31539/jks.v1i2.82

Prasojo, S., & Suprianto, B. (2019). Rancang Bangun Sistem Pengendalian Suhu Pada Inkubator Bayi Berbasis Fuzzy Logic Controller. Jurnal Teknik Elektro Volume, 08(01), 163–171.

PURNAMIATI, N. P. (2020). Analisis Kadar Bilirubin Serum Bayi Yang Mengalami Ikterus Neonatus. International Journal of Applied Chemistry Research, 1(2), 26. https://doi.org/10.23887/ijacr.v1i2.28720

Situmorang, B., Matematika, F., Ilmu, D. A. N., Alam, P., & Utara, U. S. (2021). KELEMBAPAN INKUBATOR ANAK AYAM MENGGUNAKAN SENSOR DS18B20 DAN DHT11 BERBASIS ARDUINO UNO KELEMBAPAN INKUBATOR ANAK AYAM MENGGUNAKAN.

Wisjhnuadji, T. W., Andrianto, S. B., Komputer, S., Informasi, F. T., Luhur, U. B., Utara, P., & Lama, K. (2017). BIT VOL 14 No . 2 September 2017 ISSN : 1693-9166 INKUBATOR BAYI OTOMATIS DENGAN KONTROL SUHU DAN KELEMBABAN UDARA MELALUI WEB DAN SMS ISSN : 1693-9166. 14(2), 38–43.

Zulfadli, Z. (2021). Inkubator Bayi Berbasis IOT untuk Klinik. Jurnal Sistem Informasi, 45–51. https://ojs.unimal.ac.id/sisfo/article/view/4852%0Ahttps://ojs.unimal.ac.id/sisfo/article/download/4852/2657

Additional Files

Published

19-03-2022

How to Cite

Aripin Triyanto, & Vandanu Adiputra. (2022). STUDI PENGARUH PERUBAHAN TEGANGAN DAN ARUS TERHADAP SUHU PADA ALAT INKUBATOR BAYI . OKTAL : Jurnal Ilmu Komputer Dan Sains, 1(03), 253–262. Retrieved from https://journal.mediapublikasi.id/index.php/oktal/article/view/54

Most read articles by the same author(s)