Evaluasi Kelayakan Tahanan Isolasi Instalasi Listrik pada Rumah Tinggal dengan Usia Penggunaan 50 Tahun

Authors

  • M. Syekhurohim Universitas Pamulang
  • Aripin Triyanto Universitas Pamulang
  • Budiman Universitas Pamulang

Keywords:

Installation, Insulation resistance, Revitalization, Safety, Feasibility

Abstract

Electrical installations used for more than 50 years often experience a decline in quality and pose various safety risks, such as fires, electric shocks, and damage to electrical equipment. This study aims to analyze the feasibility of electrical installations in residential homes that have been used for more than 50 years, as well as determine the need for revitalization to improve the safety and reliability of the electrical system. The research method was conducted through a quantitative approach with field surveys and technical measurements. Insulation resistance measurements were performed to assess the quality of cable insulation. The collected data includes the physical condition of cables, connectors, protective components, grounding systems, and electrical load distribution. The measurement results before revitalization showed that the insulation resistance values varied between 0.5 MΩ to 0.9 MΩ, all of which were below the minimum feasibility standard of 1 MΩ according to PUIL 2011. After revitalization, the measurement results showed a significant increase with insulation resistance values reaching 2.0 MΩ to 2.5 MΩ, ensuring that all rooms now meet the minimum feasibility standards. These findings emphasize the importance of revitalization to extend the lifespan of electrical installations and reduce safety risks. This research provides practical recommendations for homeowners and electrical technicians to conduct regular inspections and revitalization of aging electrical installations to ensure the safety and efficiency of the electrical system.

References

Alfazumi, N. F., Yandi, W., & Sunanda, W. (2020). Uji Kelayakan Instalasi Listrik di Universitas Bangka Belitung Berdasarkan PUIL 2011 (Studi di Gedung Fakultas Teknik). Seminar Nasional Teknologi Informasi Komunikasi Dan Industri (SNTKI), 7(3), 216–297.

Aryanto, N., & Jaya, A. (2022). Nova Aryanto KELAYAKAN PEMASANGAN INSTALASI LISTRIK RUMAH TANGGA DAYA 900 VA USIA 20 TAHUN SESUAI PENGELOMPOKAN PENGUJIAN INSTALASI PERSYARATAN UMUM INSTALASI LISTRIK (PUIL) 2000 STUDI KASUS DI KECAMATAN TARANO KABUPATEN SUMBAWA. Hexagon Jurnal Teknik Dan Sains, 3(2), 12–22. https://doi.org/10.36761/hexagon.v3i2.1646

Aryanto, N., Jaya, A., Elektro, T., Rekayasa Sistem, F., & Teknologi Sumbawa, U. (n.d.). KELAYAKAN PEMASANGAN INSTALASI LISTRIK RUMAH TANGGA DAYA 900 VA USIA 20 TAHUN SESUAI PENGELOMPOKAN PENGUJIAN INSTALASI PERSYARATAN UMUM INSTALASI LISTRIK (PUIL) 2000 STUDI KASUS DI KECAMATAN TARANO KABUPATEN SUMBAWA.

Binoto, M., & Utami, Y. (2022). Peremajaan Instalasi Listrik 1 Ø Rumah Tinggal Pada Warga Yang Tidak Mampu Di Desa Danyung, Kwarasan, Kecamatan Grogol, Kabupaten Sukoharjo. Abdi Masya, 2(1), 8–17. https://doi.org/10.52561/abma.v2i1.208

Irawan, A. S. (2024). Perancangan Smart Home Menggunakan Bluetooth Pada Smartphone Android Dan Arduino. OKTAL : Jurnal Ilmu Komputer Dan Science, 3(8), 2109–2115. https://journal.mediapublikasi.id/index.php/oktal

Koto, K., Tarusan, X. I., & Pesisir, K. (2013). Kelayakan instalasi listrik rumah tangga dengan pemakaian lebih dari 10 tahun di kanagarian nanggalo kecamatan koto xi tarusan kabupaten pesisir selatan. Jurnal Teknik Eletro ITP, Vol. 2 No.(2), 67.

Mikdar, S., Tri, B. H., & Puriza, Y. M. (2019). Analisis Kelayakan Instalasi Listrik Rumah Tinggal Diatas 15 Tahun Berdasarkan Puil 2011 Di Kecamatan Tanjung Pandan. Prosiding Seminar Nasional Penelitian & Pengabdian Pada Masyarakat, 152–155.

No, V., & Tahun, A. (2024). Jurnal Pengabdian Masyarakat Ilmu Terapan. 7(1), 19–24.

Nrartha, I. M. A., Sultan, S., Ginarsa, I. M., Muljono, A. B., Al. Sasongko, S. M., & Yadnya, M. S. (2021). Penyuluhan Tentang Pemeliharaan Instalasi Listrik di Desa Banyumulek, Kecamatan Kediri, Kabupaten Lombok Barat. Jurnal Karya Pengabdian, 3(1), 47–54. https://doi.org/10.29303/jkp.v3i1.88

Priajana, P. G. G., Kumara, I. N. S., & Setiawan, I. N. (2020). Grid Tie Inverter Untuk Plts Atap Di Indonesia: Review Standar Dan Inverter Yang Compliance Di Pasar Domestik. Jurnal SPEKTRUM, 7(2), 62. https://doi.org/10.24843/spektrum.2020.v07.i02.p9

Purba, J. H., & Safriandi, M. S. (2024). Analisis Nilai Tahanan Isolasi dan Tegangan Tembus pada Minyak Transformator 150 kV Sebelum dan Sesudah Purifikasi di PT Energi Listrik Batam. 16(2), 198–202.

Ramadhani, S., Harahap, R., Pelawi, Z., Kunci, K., & Batang, E. (2021). Analisis Perbandingan Nilai Tahanan Pentanahan di Gedung dan di Gardu induk pada Rumah Sakit Grand Mitra Medika Medan. Journal of Electrical Technology, 6(3).

Triyanto, A. (2023). PROTEKSI SISTEM TENAGA. UNPAM PRESS.

Triyanto, A., Gunawan, W., Kusnadi, H., & Sunardi, A. (2022). Praktikum Transformator (A. Triyanto (ed.); Issue 1). UNPAM PRESS.

Triyanto, A., Sakti, A. L., Nugraha, H., & Rifai, A. A. (2022). Operasi dan stabilitas sistem tenaga (A. Sunardi (ed.); Issue 1). UNPAM PRESS.

Wakhid, N., Haddin, M., Sukoco, B., Islam, U., Raya Kaligawe, A. J., & Tengah, J. (2019). Prosiding KONFERENSI ILMIAH MAHASISWA UNISSULA (KIMU) 2 Studi Kelayakan Instalasi Listrik Rumah Tangga Berumur Di atas 15 Tahun. 226–233.

Wangi, V. K. N., Bahiroh, E., & Imron, A. (2020). Dampak Kesehatan Dan Keselamatan Kerja, Beban Kerja, Dan Lingkungan Kerja Fisik Terhadap Kinerja Karyawan. Jurnal Manajemen Bisnis, 7(1), 40–50. https://doi.org/10.33096/jmb.v7i1.532

Z. M. Rakasiwi, D. Y. Tadeus, F. Mangkusasmito, & A. B. Putranto. (2022). Identifikasi Dan Proteksi Kebocoran Arus Listrik Pada Rumah Tangga. Berkala Fisika, 25(3), 94–104. https://ejournal.undip.ac.id/index.php/berkala_fisika/article/view/50739/0

Additional Files

Published

10-05-2025

How to Cite

M. Syekhurohim, Aripin Triyanto, & Budiman. (2025). Evaluasi Kelayakan Tahanan Isolasi Instalasi Listrik pada Rumah Tinggal dengan Usia Penggunaan 50 Tahun. OKTAL : Jurnal Ilmu Komputer Dan Sains, 4(04), 66–76. Retrieved from https://journal.mediapublikasi.id/index.php/oktal/article/view/5200

Most read articles by the same author(s)