PENGARUH VARIASI TEKANAN REFRIGERANT TERHADAP KINERJA SISTEM AIR CONDITIONER SPLIT KONVENSIONAL

Authors

  • Mardiansah Universitas Pamulang
  • Aripin Triyanto Universitas Pamulang

Keywords:

Conventional Split Air Conditioner, R22 Refrigerant, R410A Refrigerant, Refrigerant Pressure, Efficiency.

Abstract

An abstract The performance of an Air Conditioner can be influenced by the refrigerant charge. The problem arising from this is a decrease in the performance of the unit being used. The method used is to vary the refrigerant pressure value to obtain an appropriate value for the space in use. The aim of the research is to determine the recommended type of refrigerant and pressure for the split AC inside the room, achieve electrical energy consumption efficiency, and attain maximum room cooling. This research also assists in providing practical guidance for owners of conventional Split Air Conditioners and technicians in maintaining the optimal performance of their systems. The results of the research indicate that the highest temperature for the R22 type is at 26˚C and for R410A at 25˚C in a 3 x 3-meter room. The measured current value for R22 is 2.6 Ampere and for R410, it is 2.2 Ampere, with the voltage for R22 at 222 V and R410A at 221 V.

References

Ahsani, M., & Prijo Budijono, A. (2015). Rancangan Bangun Pendingin Ruangan Portable dengan Memanfaatkan Efek Perbedaan Suhu pada Thermo Electric Cooler (TEC). JRM. Volume 03 Nomor 01 Tahun 2015, 100-109, 03, 100-109Ahsani, M., Prijo Budijono, A. (2015). Ra.

Bahctiar, W. A., Hariyadi, S., & Utomo, W. (2020). RANCANG BANGUN SIMULATOR PENGUKURAN TEKANAN , ARUS LISTRIK , DAN SUHU PADA AIR CONDITIONING SYSTEM 1 PK DENGAN MENGGUNAKAN REFRIGERANT R32. 1–8.

Imam, A. (2020). Jurnal Inovator Pengaruh Tekanan Refrigeran R-134a Terhadap Nilai Coefficient of Performance ( COP ). 4(2), 9–12.

Pratama, F. A., Mitrakusuma, W. H., Muhamad Anda Falahuddin, & Ayu, W. S. (2021). Kajian kinerja sistem refrigerasi menggunakan refrigeran R32, R22 dan R1270 menggunakan REFPROP. Prosiding The 12th Industrial Research Workshop and National Seminar, 472-477.

Triyanto, A. (2023). PROTEKSI SISTEM TENAGA. UNPAM PRESS.

Triyanto, A., Firasanto, G., Mualim, E., Agus, D., & Utomo, L. (2022). Implementasi dan Sosialisasi Prototipe Panel Surya 30 WP sebagai Pembelajaran di Lab SMK Khazanah Kebajikan Pondok Cabe Pamulang , Tangerang Selatan. 2(6), 1849–1856.

Triyanto, A., Sakti, A. L., Nugraha, H., & Rifai, A. A. (2022). Operasi dan stabilitas sistem tenaga (A. Sunardi (ed.); Issue 1). UNPAM PRESS.

Additional Files

Published

05-12-2023

How to Cite

Mardiansah, & Aripin Triyanto. (2023). PENGARUH VARIASI TEKANAN REFRIGERANT TERHADAP KINERJA SISTEM AIR CONDITIONER SPLIT KONVENSIONAL. OKTAL : Jurnal Ilmu Komputer Dan Sains, 2(12), 3145–3150. Retrieved from https://journal.mediapublikasi.id/index.php/oktal/article/view/3867

Most read articles by the same author(s)