Analisa Aliran Daya Sistem Distribusi Kelistrikan Pada Gedung PT. X

Authors

  • Ghani Ikhsan Priyambudi Universitas Pamulang
  • Ojak Abdul Rozak Universitas Pamulang

Keywords:

Aliran Daya Listrik, Sistem Distribusi, Trafo, Tegangan, Arus

Abstract

The 3-phase, balanced electrical system is always solved per phase and displayed in a line diagram that matches the system. The purpose of the line diagram is to provide all the information you need. In various cases, the diagram will vary depending on the problem being solved. The use of technology in this project is the analysis of the power process from the Mega Watt (MV) distribution field, transformers, and low voltage electrical distribution systems. The purpose of this study is to measure the distribution of electrical output from the MV panel to both transformers to reduce the voltage from 60 kV to 380 volts and calculate the transformer voltage that comes from 20 kV to 380 volts or 400 volts. The amount of imbalance and stability results are less than 3%, as a result of the measurement stability results of 0.2% on the panel curve containing and 0.25% on the tension of the outgoing PUTR panel. The value of imbalance and electrical stability results from the PUTR 1.66% output panel is 2.97% and at PUTR 2 is 4.66%. To ensure that the imbalance is below 5%.

References

Armansyah, & Sudaryanto. (2016). Pengaruh Penguatan Medan Generator Sinkron Terhadap Tegangan Terminal. Journal of Electrical Technology.

Idris, A. R., Usman, & Suyono, W. (2021). Analisis Pengaruh Pemasangan Counterpoise pada Tower Transmisi Saluran Udara Tegangan Tinggi 70 kV Line Mandai-Pangkep. Prosiding Seminar Nasional Teknik Elektro dan Informatika (SNTEI) 2021, 6.

Julianto, P., & Sumardi. (2018). Analisa Aliran Daya Pada Jaringan Distribusi 20 KV PT. PLN (Persero) Sebatik Menggunakan Software Etap Powerstation 12.6. 0. Elektrika Borneo. KDMFAB. (2024, November 19). kdmfab. Diambil kembali dari Memahami Prinsip Kerja Transformator – Panduan Lengkap: https://kdmfab.com/id/prinsip-kerja-transformator/ Nigara, A. G., & Primadiyono, Y. (2015). Analisis Aliran Daya Sistem Tenaga Listrik pada Bagian Texturizing di PT Asia Pasific Fibers Tbk Kendal menggunakan Software ETAP Power Station 4.0. Jurnal Teknik Elektro Vol. 7 No. 1, 4.

Priambodo, P., Penangsang, O., & Wibowo, R. S. (2013). Analisis Aliran Daya Tiga Fasa TidakSeimbang Menggunakan MetodeK-Matrikdan Z-BR pada Sistem Distribusi20 kV Kota Surabaya. Digilib. its, 32.

Prinsip Kerja Generator Sinkron. (2019, Mei). Diambil kembali dari edukasikini: https://www.edukasikini.com/2019/05/prinsip-kerja-generator-sinkron.html

Ridwan, & Pratama, M. F. (2021). Investigasi dan Mitigasi Tegangan Lebih dan Arus Lebih Feroresonansi Dalam Saluran Transmisi 150kV Gardu Induk Dago Pakar.

Salman, R., Mustamam, & Sinuraya, A. (2014). Simulasi dan Analisis Aliran Daya Pada Sistem Tenaga Listrik Menggunakan Perangkat Lunak Electrical Transient Analyser Program (Etap) Versi 4.0. Jurnal Pendidikan Teknologi dan Kejuruan, 8.

Sawiji, E., & Tambunan, J. M. (2019). Analisis Sistem Distribusi Kabel Bercabang Dengan Kabel Konvensional di Apartemen Ancol Mansion. Energi dan Kelistrikan Jurnal Ilmiah, 10.

Siswanto, A., Baehaqi, M., Alif, M., & Mansur. (2024). Analisa Overhaul Aliran Beban PMT GI 150/70 kV Menggunakan ETAP pada SUTT 70 kV. Jurnal Sains dan Teknologi.

Supriyadi, A. (2016). Analisa Aliran Daya Pada Sistem Tenaga Listrik Menggunakan Software Etap 12.6. FORUM TEKNOLOGIVol. 06 No. 3.

Utomo, P. (2019). Studi Analisis Kualitas Transformator Daya Gardu. Journal Of Electrical Engineering, Energy, And Information Technology, 11.

Warisanto, D. (2018). Analisis Perbandingan Efisiensi Sistem AC dan DC pada Beban Residensial Menggunakan Software Etap.

Winasis, & Nugraha, A. W. (2007). Pengaruh Pemasangan Kapasitor Shunt Terhadap Konsumsi Daya Aktif Instalasi Listrik. Dinamika Rekayasa Vol. 3 No.1 Februari 2007. Wirandi, M., & Justiadi. (2020). Analisis AAliran Daya Pada Jalur Kelistrikan Gedung Menggunakan Aplikasi Etap 12.6.0. Proceeding SENDIU, 7.

Published